A Comparison of Bit-serial Systolic Array Implementations of Spectral Analysers

Neil Bergmann

Cited by 0Abstract and details only

Abstract

The equations describing two spectral estimators for non-stationary signals - the Short-Time Fourier Transform and the Discrete Wigner Ville Distribution, and their implementations using the FIRST silicon compiler, based on bit-serial systolic array architectures is described. Both designs were simulated, and could achieve a speed of 500,000 3.2-point spectra per second. The performance of the DWM analyser is shown to be superior in terms of both spectral accuracy and chip count.