Skip to content
Free planNo credit card requiredStart writing

article · Ophthalmology Research An International Journal · 2017

Mechanical Pupil Dilatation Using Oasis Ring versus Non-mechanical Device Pupil Dilatation for Phacoemulsification in Eyes with Narrow Pupil

Mohammad M. Khater, Ahmed Ghoneim

Cited by 0Open access

Abstract

Purpose: to compare using Oasis ring for mechanical dilatation of the pupil during phacoemulsification in cases of narrow pupil with non-mechanical dilatation.Methods: this study included 80 eyes of 67 patients of cataract with narrow pupil divided into 2 groups each of them included 40 eyes. In one group, Oasis ring was used to achieve adequate pupillary dilatation while in the other group, non-mechanical methods as bi-manual stretching, visco-mydriasis and partial sphincrotomies were used. Both groups were compared regarding achieved pupil size, additional time for dilatation, intra-operative difficulties and post-operative pupil characters after one month. This study was conducted at Tanta University Hospital in Egypt.Results: We found that the mean pupil size was 6.00±0.00 mm Oasis ring group while was 4.26±0.48 mm in the other group. Dilatation needed longer time with Oasis ring where it ranged from 83- 117 seconds. There was more liability for intra-operative difficulties as iris prolapse, minimal bleeding and iris trauma in the non-mechanical group. Post-operative pupil characters were rounded, central and reactive in the first group while oval pupil was found in 17.5% and minute tears in 12.5% of cases of non-mechanical group.Conclusion: Oasis ring offered more pupil dilatation with less liability for intra-operative complications and preservation of pupil characters. It added more cost and time to achieve adequate pupil dilatation.

Cite this paper

APA 7

Khater, M. M., & Ghoneim, A. (2017). Mechanical Pupil Dilatation Using Oasis Ring versus Non-mechanical Device Pupil Dilatation for Phacoemulsification in Eyes with Narrow Pupil. Ophthalmology Research An International Journal, 7(2), 1–6. https://doi.org/10.9734/or/2017/35985

MLA 9

Khater, Mohammad M., and Ahmed Ghoneim. “Mechanical Pupil Dilatation Using Oasis Ring versus Non-mechanical Device Pupil Dilatation for Phacoemulsification in Eyes with Narrow Pupil.” Ophthalmology Research An International Journal, vol. 7, no. 2, 2017, pp. 1–6, https://doi.org/10.9734/or/2017/35985.

Chicago

Khater, Mohammad M., and Ahmed Ghoneim. 2017. “Mechanical Pupil Dilatation Using Oasis Ring versus Non-mechanical Device Pupil Dilatation for Phacoemulsification in Eyes with Narrow Pupil.” Ophthalmology Research An International Journal 7 (2): 1–6. https://doi.org/10.9734/or/2017/35985.

Harvard

Khater, M.M. and Ghoneim, A. (2017) ‘Mechanical Pupil Dilatation Using Oasis Ring versus Non-mechanical Device Pupil Dilatation for Phacoemulsification in Eyes with Narrow Pupil’, Ophthalmology Research An International Journal, 7(2), pp. 1–6. Available at: https://doi.org/10.9734/or/2017/35985.

BibTeX
@article{khater2017mechanical,
  title = {{Mechanical Pupil Dilatation Using Oasis Ring versus Non-mechanical Device Pupil Dilatation for Phacoemulsification in Eyes with Narrow Pupil}},
  author = {Khater, Mohammad M. and Ghoneim, Ahmed},
  journal = {Ophthalmology Research An International Journal},
  volume = {7},
  number = {2},
  pages = {1--6},
  year = {2017},
  doi = {10.9734/or/2017/35985}
}

Made from the index record. Check names, capitalisation and page numbers against the paper. Need another style? AI for Research has over 10,000.