United States. Nim Committee., United States. Department of Energy. Division of Biomedical and Environmental Research. · The Journal of the Abraham Lincoln Association
Cited by 0Open access
None · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · 1978
Several Department of Energy and IEEE Standards and reports are concerned with the CAMAC modular instrumentation and digital interface system. Since, these documents are under continual review, clarifications, corrections and modifications are made from time to time. This supplement compiles all such material in a single document that is to be revised and reissued as necessary.
Cited by 4Open access
Boler, Frances M., Swanson, P. L. (Peter L.) · The Journal of the Abraham Lincoln Association
Cited by 0Open access
A.V. Golubev, I.K. Muraviev, I.A. Peresypkin et al. · Vestnik IGEU · 2026
Computer simulators are widely used to train operators, technical and maintenance personnel at thermal and nuclear power plants (TPPs and NPPs). The use of training simulators provides power plant employees with the opportunity to gain valuable practical experience in case of emergency situations when technological processes deviate from normal operation. At the same time, operating personnel in the thermal automation and measurement (TAM) and process control systems (PCS) shops perform a vital function at the power plant. They ensure the performance monitoring and maintenance of all hardware and software components of the PCS of power unit. However, the training methods used at TPPs and NPPs for operating personnel in the TAM and PCS shops (theoretical training, on-the-job training for maintenance and operating personnel in the TAM and PCS shops) lag behind the current pace of industry development. The aim of the study is to develop an interactive simulator for training operational personnel of thermal automation and measurement shops and automated process control systems with virtual modeling of the field instrumentation and automation zone. The training system is supported by hardware and software located on the server side of the simulator running the Linux operating system. The programmer toolset is the specialized SIM-2000 software suite. Testing and debugging of the developed field-level equipment models (sensors and connection lines) have been conducted using the SimInTech dynamic simulation environment. A visualization subsystem for instrumentation and automation equipment (I&A) has been developed for TPP field equipment. This subsystem integrates developed models of sensors, devices, and actuators (AM) into modern computer simulators for power units, providing realistic visual modeling of field equipment. I&A device models have been developed that enable diagnostics of the condition of sensors and AM, adjusting their process connections to power lines, if necessary, as well as configuring them, checking their functionality, and monitoring their connections to the software and hardware suite and other devices. The obtained results enable comprehensive training for the operational shift personnel of the unit to solve the problem of control, maintenance, and troubleshooting of instrumentation and automation equipment.
Cited by 0Open access
Walter J. Layer · IEEE Transactions on Instrumentation and Measurement · 1969
A computer-oriented program for control and dissemination of measurement parameters as applied in a metrology laboratory is described. The program includes the capability for automated data readout of certain measurement systems as process inputs, computer storage and statistical analysis of "absolute" values of fixed standards, computer data computation incorporating all known information on measurement-system entities, and parameter status control. The preparation of reports of calibration by computer output is provided for repetitive services. Operational details of the program as applied to the dc/LF region of capability are discussed.
Cited by 1
Clarence A. Semple, John C. Cotton, Dennis J. Sullivan · 1981
Abstract : This report presents relationships between aircrew training device (ATD) instructional support features and training requirements. Instructional support features include ATD hardware and software capabilities that permit instructors to manipulate, supplement or otherwise control student learning experiences. The instructional features addressed are freeze; automated demonstrations; record and replay; automated cuing and coaching; manual and programmable sets of initializing conditions; manual and programmable malfunction control; atd-mounted audio visual media; automated performance measurement; automated performance alerts; annunciator and repeater instruments; closed circuit television; automated adaptive training; programmed mission scenarios; automated controllers; graphic and text readouts of controller information; computer controlled threats; computer managed instruction; recorded briefings; debriefing aids; and hardcopy printouts. Each feature is discussed, as appropriate, in terms of its operation, related features, instructional values, observed applications, utility (use-related) information, related research, and design considerations. (Author)
Cited by 8
R. Sunder · 1990
An automated fatigue and fracture laboratory was recently set up at the National Aeronautical Laboratory. Six servohydraulic load frames are connected to a single multi-user, time-sharing computer system, through dedicated microprocessor-based interfaces. The host computer system includes resources for post processing of test data, output of test results and their storage and retrieval. Application software was developed for automated crack growth testing under a variety of constant-amplitude and spectrum load test conditions including K-control and on-line fatigue cycle analysis. Automated crack length measurement is through unloading compliance.
Cited by 3
Xingguang Geng, Fei Yao, Weiwei Tian et al. · Frontiers in artificial intelligence and applications · 2025
The quality testing of traditional Chinese medicine injection (TCMI) provides quantitative indicators for its safety evaluation, improving quality control and reducing adverse reaction rates. However, no automated Microtox-based testing equipment currently exists globally, necessitating manual intervention in the entire process. To address this, our team developed an automated TCMI quality testing system using Microtox technology. By integrating manual workflows and standardizing reusable technologies, the instrument comprises three modules: a mixing-resuscitation module, a mechanical pipetting module, and a light intensity measurement module. Centralized computer control enables fully automated TCMI quality testing. Experimental results demonstrate strong consistency between manual and automated testing, with reduced human-induced measurement errors and enhanced data reliability for TCMI quality assessment.
Cited by 0Open access
Jennifer Bowers, D L Bullard, T. R. Schelp · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · 1978
A flexible test system is studied and proposed to provide an extensive evaluation and testing capability for telemetry products. A distributed computer controlled, modular unit test system using Computer Automated Measurement and Control (CAMAC) standard hardware and compatible software is selected because of its flexibility of application and long term cost effectiveness.
Cited by 0Open access
Cynthia Williamson And, Cynthia K. Williamson, Russell J. De Young · 2000
A 6-MHz 16-bit waveform digitizer was evaluated for use in atmospheric differential absorption lidar (DIAL) measurements of ozone. The digitizer noise characteristics were evaluated, and actual ozone DIAL atmospheric returns were digitized. This digitizer could replace computer-automated measurement and control (CAMAC)-based commercial digitizers and improve voltage accuracy. Introduction The waveform digitizer is a critical component of lidar detection systems; it transforms the analog detector output into a digital signal by measuring the signal voltage in a discrete time interval determined by an external clock. The accuracy of the digital voltage level increases with the digitizer bit level. Technology has advanced to the point where 8- and 12-bit waveform digitizers are commercially available and commonly used in computer-automated measurement and control (CAMAC) crates, which are readily interfaced to computer systems. These systems have worked well for ground and aircraft-borne...
Cited by 0
Bernhard Ziegnerr · 1987
An automated wafer level RF/DC test system useful to frequency above 20 GHz has been developed to characterize and determine acceptability of microwave semiconductor die prior to dicing the wafer. This concept has been implemented by the integration of a programmable wafer prober with both an automated DC and RF automatic network analyzer. The entire measurement is under computer control.
Cited by 0
M.L. Roberts, Thomas L. Moore · University of North Texas Digital Library (University of North Texas) · 1990
LLNL has successfully implemented a distributed computer control system for automated operation of an FN tandem accelerator. The control system software utilized is the Thaumaturgic Automated Control Logic (TACL) written by the Continuous Electron Beam Accelerator Facility and co-developed with LLNL. Using TACL, accelerator components are controlled through CAMAC using a two-tiered structure. Analog control and measurement are at 12 or 16 bit precision as appropriate. Automated operation has been implemented for several nuclear analytical techniques including hydrogen depth profiling and accelerator mass spectrometry. An additional advantage of TACL lies in its expansion capabilities. Without disturbing existing control definitions and algorithms, additional control algorithms and display functions can be implemented quickly. 5 refs., 1 fig.
Cited by 0Open access
G. Davis, D.L. Mansur, W.D. Ruhter et al. · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · 1994
This report presents the details of the Lawrence Livermore National Laboratory safeguards and securities program. This program is focused on developing new technology, such as x- and gamma-ray spectrometry, for measurement of special nuclear materials. This program supports the Office of Safeguards and Securities in the following five areas; safeguards technology, safeguards and decision support, computer security, automated physical security, and automated visitor access control systems.
Cited by 0Open access
J. M. Sorvari · 1978
Abstract : An automated photometer designed to measure atmospheric extinction and sky brightness has been implemented. The measurement routines are primarily under computer control and require a minimum of operator intervention. A description of the theory and operation of the system is given, and the text concludes with a discussion of the use of the automated system in the context of the GEODSS mission. (Author)
Cited by 0
Paulo Escandón-Panchana, Fernando Morante-Carballo, Gricelda Herrera-Franco et al. · Mathematical Modelling and Engineering Problems · 2022
Refineries, fuel depots, airports and storage terminals commonly use fluid level measurement in storage tanks. Different fluid level measurement techniques and devices differ in the inaccuracy of measurement results, costs, and company needs. In addition, these measurements seek reliability of measurement data, immediate response times, control in operations, oil movement, custody transfer and inventory control. The objective is to develop a computer system for measuring fluid levels in oil storage tanks, using ultrasonic and temperature sensors, creating a web application for an automated measurement system (SAM) for managing volumes of Petroleum. The study methodology is i) Analysis of measurement reports. ii) Selection of physical components of the computer system. iii) SAM algorithm design and web application, and iv) Validate the system. The SAM application developed in open source proposes functional modules for administration, control, security, management and monitoring of storage tanks, the status of physical components and generation of dynamic reports in real-time. The results show the control characteristics of storage tanks such as maximum and minimum volume, temperature, time, precise data records in less time than certain current computer structures.
Cited by 5Open access
D.C.G. Pearton, Carl Heron · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · 1983
A description of the automated microphotometer and its operation is given, which includes measurement under computer control. Speed and precision tests indicate that the system is superior in every respect to that in which an analyst reads the photoplates in spark-source mass spectrometry.
Cited by 0
Nakamura, Matthew, Heyes, Corrisa, Wakumoto, Kody · Zenodo (CERN European Organization for Nuclear Research) · 2025
Computer vision tool for automated analysis of can rim circularity and quality control in manufacturing. Provides measurement of circular deviation, diameter accuracy, and out-of-round characteristics of cylindrical objects with 3D reconstruction capabilities. Includes batch processing capabilities and multiple detection methods for robust rim analysis.
Cited by 0Open access
Nakamura, Matthew, Heyes, Corrisa, Wakumoto, Kody · Zenodo (CERN European Organization for Nuclear Research) · 2025
Computer vision tool for automated analysis of can rim circularity and quality control in manufacturing. Provides measurement of circular deviation, diameter accuracy, and out-of-round characteristics of cylindrical objects with 3D reconstruction capabilities. Includes batch processing capabilities and multiple detection methods for robust rim analysis.
Cited by 0Open access
Jordan Clark, Georgianne Huff · University of North Texas Digital Library (University of North Texas) · 1978
An Analytical Chemistry Measurements Quality Control Program assures the reliability of analytical measurements performed at the Barnwell Nuclear Fuel Plant. The program includes training, methods quality control, replicate samples and measurements, mass measurements, interlaboratory sample exchanges, and standards preparation. This program has been designed to meet the requirements of 10CFR70.57. Portions of the program have been automated by using a PDP 11/35 computer system to provide features which are not readily available in manual systems. These include such items as realtime measurement control, computer calculated bias and precision estimates, various surveillance applications, and evaluation of measurement system variables. The efficiency of the computer system has been demonstrated in gathering and assimilating the results of over 1100 quality control samples during a recent cold chemical checkout campaign. These data were used to determine equations for predicting measurements reliability estimates; to evaluate measurement performance of the analysts, equipment, and measurement period; and to provide directions for chemistry methods modifications and additional training requirements. A procedure of replicate sampling and measuring provides random error estimates. The analytical chemistry measurement quality control activities during the campaign represented about 10% of the total analytical chemistry effort.
Cited by 0Open access
Williamson, Cynthia K., DeYoung, Russell J. · NASA Technical Reports Server (NASA)
A 6-MHz 16-bit waveform digitizer was evaluated for use in atmospheric differential absorption lidar (DIAL) measurements of ozone. The digitizer noise characteristics were evaluated, and actual ozone DIAL atmospheric returns were digitized. This digitizer could replace computer-automated measurement and control (CAMAC)-based commercial digitizers and improve voltage accuracy.
Cited by 0Open access